Categories

News

NDN Calibration Laboratory with accreditation!

In July 2022, our Calibration Laboratory received accreditation with the number AP 209 granted by the Polish Center for Accreditation (PCA) under the EA MLA international agreement. Thus, the Laboratory confirmed compliance with the requirements of PN-EN ISO/IEC 17025 "General requirements for the competence of testing and calibration laboratories" in the field of calibration of electrical quantities.

Read more...

News

IT7622 ITECH laboratory power supply - 7600 series

Manufacturer:

ITECH
Price:

61 500,00 złbrutto

40 000,00 zł netto
49 200,00 zł brutto (23% VAT)

The price has not changed

Ask about product

FEATURES:

TECHNICAL SPECIFICATIONS:

ModelIT7622IT7624IT7626
AC input
Voltage220V±10%or 110V±10%220V±10%or 110V±10%220V±10%
Phase
Frequency47-63Hz
MAX current20A / 40A30A / 60A60A
Power factor (PF)0.7 (standard)
AC output
MAX output power750VA1.5kVA3kVA
VoltageRangeHigh: 2-300V; Low: 1-150V; Auto: 1-150V/2-300V
Resolution10mV
Accuracy± 0.2%+ (0.2%+0.2%×Kfreq)×FS*2
Currentrms0-6 Arms (1-150 Vac)0-12 Arms (1-150 Vac)0-24 Arms (1-150 Vac)
0-3 Arms (2-300 Vac)0-6 Arms (2-300 Vac)0-24 Arms (1-150 Vac)
peak0-18 Apeak (1-150 Vac)0-36 Apeak (1-150 Vac)0-72 Apeak (1-150 Vac)
0-9 Apeak (2-300 Vac)0-18 Apeak (2-300 Vac)0-36 Apeak (2-300 Vac)
Output frequency10-5000 Hz
Output phase
Harmonic content factor≤0.5% at 10-500 Hz (Resistive Load)
≤2% at 501-5000 Hz (Resistive Load)
Peak factor3
Linear adjustment≤0.1% FS (Resistive Load)
Load adjustment≤0.5% FS (Resistive Load)
Dynamic response time≤100 μs (typical)
DC output
MAX output power375 W750 W1.5 kW
VoltageRange± 212 V / ±424 V *6
Resolution10mV
Accuracy ()± (0.2%+0.2% FS)*7
CurrentRange3 A / 1.5 A6 A / 3 A12 A / 6 A
Resolution10 mA
Accuracy ()± (0.3%+0.3% FS)*7
Accuracy of the power meter± (0.4%+0.4% FS)*7
Voltage ripplepeak300 mVp-p
rms150 mVrms
Meter
AC voltageRange0-300 Vac
Resolution10 mV
Accuracy± (0.2%+0.2% FS)
AC current (rms)Range0-6 Arms0-12 Arms0-24 Arms
Resolution10 mA
Accuracy± 0.3%+(0.3%+0.2%×Kfreq)×FS*2
AC current (peak)Range0-18 Apeak0-36 Apeak0-72 Apeak
Resolution10 mA
Accuracy± 0.3%+(0.3%+0.2%×Kfreq)×FS*2
PowerResolution10 mW
Accuracy± 0.4%+(0.4%+0.2%×Kfreq)×FS*2
Phase shiftRange0-360°
Resolution
Accuracy± 1°(45-65 Hz)*5
FrequencyRange10-5000 Hz
Resolution0.1 Hz
Accuracy± 0.1%+0.1 Hz (10 Hz-999.9 Hz) / ± 0.1%+1 Hz (1 kHz-5 kHz)*4
Other
ConnectorsGPIB / USB / LAN / RS323 / CAN
Dimensions3U3U6U
To download this file you need to be logged. Please Sign in or register.