Categories

News

WT310E Yokogawa Power Meter

Manufacturer:

YOKOGAWA
Price:

Please contact us
Priced individually

Ask about product

  • Basic accuracy of 0.1%
  • DC measurement bandwidth, 0.1Hz - 100kHz
  • Measurement of all AC and DC parameters
  • In USB and GPIB or RS232 standard
  • Measurement of small currents of the order of 50uA
  • Fast data update (up to 10 readings /s)
  • Optional Ethernet interface

The WT300E's wide range of functions and enhanced specifications, allows handling of all the measurement applications from low frequency to high frequency inverters using a single power meter.

Accuracy with fast display and update rate:
The WT300E series with the fast display update rate of 100ms, offer's engineers a short tact time in their testing procedures. The basic accuracy for all input ranges is 0.1% rdg + 0.05% rng (50/60Hz) and DC 0.1% rdg + 0.2% rng.

Simultaneous Measurement:

U/I/P/Freq/Integ(+/-)/Harmonics components/ THD with max. 100ms cycle.

In addition to standard power measurements, the WT300E series measures all DC and AC parameters. Additionally, the WT300E series can measure harmonics and perform integration simultaneously without changing the measurement mode. The accompanying WTViewerFreePlus software can monitor and save the 200 parameters used.

Auto ranging function available in selected ranges.

The auto-range function is used to select or change the ranges automatically, within specified ranges. This results in shorter range changing times, allowing more efficient testing.

Auto Ranging Function For Integration Measurement
Typically, when power meters operate in an integration mode to measure power consumption and standby power, the measuring ranges need to be fixed. However, if the level of the input exceeds the maximum of the selected range, the test will need to be repeated. The WT300E Series has a high-speed automatic ranging capability in integration mode, which removes the need to repeat any test.

Bandwidth: DC and 0.1Hz to 100 kHz (WT310EH is up to 20 kHz for 40A).

Direct Input: Maximum direct input of up to 600V and 20A, or 40A(incase of WT310EH). The wide current input ranges on the WT310E series, give users the option to measure current as low as 50 micro-Amps to as high as 40Arms(incase of WT310EH).

High-speed data update (up to 10 readings per second.).

COMPARISON TABLE WITH PREVIOUS VERSIONS:

Enhancement points from the WT310/WT330

Changed points from the WT210/WT230

WT300E Series
WT300 Series
WT210/WT230
Basic power measurement accuracy (50/60 Hz)0.1% of reading + 0.05% of range
0.1% of reading+0.1% of range
0.1% of reading+0.1% of range
Influence of power factorWhen power factor (λ)= 0 (S: apparent power) ±0.1% of S for 45 Hz ≤ f ≤ 66 HzWhen power factor (λ)= 0 (S: apparent power) ±0.2% of S for 45 Hz ≤ f ≤ 66 HzWhen power factor (λ)= 0 (S: apparent power) ±0.2% of S for 45 Hz ≤ f ≤ 66 Hz
Frequency bandwidth
DC, 0.1 Hz to 100 kHz (WT310EH DC, 0.1 Hz to 20 kHz)
DC, 0.5 Hz to 100 kHz (WT310H DC, 0.1 Hz to 20 kHz)
DC, 0.5 Hz to 100 kHz
Direct input current range
WT310E: 12 ranges/5 mA to 20 A, WT310EH: 6 ranges/1 to 40 A WT332E/WT333E: 6 ranges/0.5 to 20A
WT310: 12 ranges/5 mA to 20 A, WT310HC: 6 ranges/1 to 40 A WT332/WT333: 6 ranges/0.5 to 20A
WT210: 12 ranges/5 mA to 20 A, WT230-2ch/WT230-3ch: 6 ranges/0.5 to 20A
External current input

EX1:2.5/5/10[V] EX2:50m / 100m / 200m / 500m / 1 / 2[V](OP)

EX1:2.5/5/10[V] EX2:50m / 100m / 200m / 500m / 1 / 2[V](OP)
EX1: 2.5/5/10[V] EX2:50m / 100m / 200m / 500m / 1 / 2[V](OP)
Expansion of effective input range for voltage & current (CF=6A)
2% to 260%*1
No
No
Expansion of maximum displaying value for voltage & current (CF=6A)2% to 260%*2
No
No
Simultaneous measurement of RMS, Voltage MEAN & DC
Yes*3
Yes*3
No
Frequency measurement
2 channels (voltage & current)
2 channels (voltage & current)
Selected voltage or current (one)
Number of display item
4 items
4 items
3 items
Sampling rate
Approximately 100 kS/s
Approximately 100 kS/s
Approximately 50 kS/s
Data update rate
100m/250m/500m/1/2/5/10/20 sec, Auto
100m/250m/500m/1/2/5 sec
100m/250m/500m/1/2/5 sec
Harmonic measurement
Yes (OP/G5)
Yes (OP/G5)
Yes (OP/HRM)
THD calculation maximum order setting
Yes (OP, 1 to 50th)
Yes (OP, 1 to 50th)
No
Auto ranging of integration
Yes
Yes
No
Communication InterfaceUSB
Yes
Yes
No
GP-IBYes GP-IB or RS-232Yes GP-IB or RS-232No
RS-232Yes GP-IB or RS-232Yes GP-IB or RS-232Yes (OP) GP-IB or RS-232C
EthernetYes (OP)Yes (OP)Yes (OP) GP-IB or RS-232C
Modbus/TCP (Ethernet)Yes (OP,/C7)NoNo
IEEE standard for GP-IBIEEE488.2IEEE488.2

IEEE488.1 or IEEE488.2

Comparator functionYesYesYes
Viewer software (setting & data capturing)Free (included)Free (included)Free (download)

*1: WT310EH input range is 2% to 260% (20 A range only up to 200%)
*2: WT310EH input range is 2% to 280% (20 A range only up to 220%)
*3: Simultaneous, mode independent measurement using the WTViewerFreePlus PC software.
*: A command compatible mode for the previous WT200 series is available. (IEEE488.2 only) In that mode, the WT300E series and WT300 series works identically to a WT200 series except for the Store (and recall operation) and the Compare functions.
*: Modbus/TCP communication requires /C7 Ethernet option.

To download this file you need to be logged. Please Sign in or register.