CHAUVIN ARNOUX C.A 6547 insulation resistance meter
FEATURES
- Robust housing with IP53 protection rating
- Electrical safety: IEC 61010-1 1000 V CAT III (2500 V CAT I) - IEC 61557
- Large, monochrome, backlit, LCD display with bargraph
- Built-in 128 kB memory for recording measurement results
- Measurement:
Insulation resistance from 10 Ohms to 10TOhm with fixed test voltage thresholds of selectable 500, 1000, 2500, 5000 V DC, or other user-settable test voltages from 40 to 5100 V DC (with steps of 10 or 100 V DC)
Voltages from 1 to 5100 V AC/DC (frequency from 15 Hz to 500 Hz or DC)
Capacitances from0.005 to 49.99 ?F
Leakage currents from0.001 nA to 3000 ?A
- Calculation of insulation quality factors: DAR, PI, DD
- Testing the value of insulation resistance as a function of time - recording the results to memory
- "Smoothing" function of measurement results (improving the stability of the indication)
- Configurable alarms with signaling of overrun by means of a sound signal and indication on the display
- Timer function; programming of test time
- RS232 bi-directional communication interface
- Optional PC DataView software for PC connection to the instrument and advanced measurement analysis
- Possibility to directly connect a printer with serial input or a printer with parallel input (using a special converter)
- Power supply: rechargeable NiMH battery
- Dimensions: 270 mm x 250 mm x 180 mm
- Weight: 4.3 kg