FEATURES:
TECHNICAL DATA:
VOLTAGE | Output voltage | 18V |
Load adjustment | <0.01 + 3mV (<=3A), <0.02% + 5mV (<=10) | |
Linear regulation | <0.01 + 3mV | |
Setting resolution | 10mV | |
Reading resolution | 10mV (<20V) / 100mV (>=20V) | |
Setting accuracy | <0.05% + 10mV | |
Reading accuracy | <0.05% + 15mV (<20V) / <0.05% + 120mV | |
Attenuation (20Hz-20MHz) | 3mV (Vpp), 0.5mV (Vrms) | |
Temperature coefficient | <0.02% + 5mV | |
CURRENT | Output current | 5A |
Load regulation | <0.01% + 3mA | |
Linear regulation | <0.1% + 2mA | |
Resolution of settings | 10mA | |
Readout resolution | 10mA | |
Setting accuracy | 0.2% + 10mA | |
Reading accuracy | <0.1% + 15mA | |
Attenuation (20Hz-20MHz) | 5mA (Irms) | |
Temperature coefficient | <0.1% + 5mA | |
Power | 90W | |
Dimensions (w*w*g) | 214.5 * 88.2 * 354.6 [mm]. | |
Weight | 7.8 kg |