The DI-6200 insulation tester has a wide range and high accuracy for measuring insulation resistance. The device allows us to use both high and low-ohm ranges. The contrast LCD display makes it much easier to read even in low-light conditions and provides low power consumption.
Display | LCD, 18mm (0.7 "), maximum reading 1999 |
Measuring ranges | 200MW / 500 V, 1000MW / 1000 V, 200 W / OHMS |
Sampling period | 0,4 s. |
Measurement time on MW ranges | Approximately 2.5 seconds |
Range resetting | automatic |
Overfill indicator | displayed "1" |
Power source | 12 V DC - 8 batteries 1.5V type AA (alkaline or heavy duty recommended) |
Power supply current consumption | approx. 100mA (1000MW/1000Vrange); approx. 50mA (200MW/500V range) approx. 1.6mA (200W range) |
Operating temperature | 0°C to 50°C |
Permissible humidity | less than 80% RH |
Dimensions and weight | 170 x 127 x 78 mm; 560 g |
Equipment | User's manual, pair of cables with crocodile clips type AL-03 |
High-ohm range (MOHM) | ||||
Range | Accuracy | Resolution | Test voltage (open input) | Remarks |
200MW (500 V) | ± (3% + 1 digit) | 0.1MW | approx. 480 V (>7MW) approx. 475 V (5 ÷7MW) | Short-circuit current: approx. 0.4 mA |
1000MW (1000 V) | ± (3% + 1 digit) | 1MW | approx. 980 V (>7MW) approx. 950 V (5 ÷7MW) | Short-circuit current: approximately 0.7 mA |
Low-ohmic range (OHM) | ||||
200 W | ± (1% + 1 digit) | 0,1 W | approximately 5 V | Overload resistance: 500V AC/DC (for 20 minutes) |
Data sheet