CHAUVIN ARNOUX E6N current probe.
Parameters:
- Measurement of AC and DC current from 5 mA to 80 A in two ranges:
Range1: 5 mA - 2 A DC; 5 mA - 1.5 A AC
Range 2: 20 mA - 80 A DC/AC
- Bandwidth: DC - 2 kHz (range 1); DC - 8 kHz (range 2)
- Sensitivity: 1 V/A (range 1); 10 mV/A (range 2)
- Output signal:
Range 1: 1 V DC/AC per 1 A DC/AC (2 V DC for 2 A DC or 1.5 V AC for 1.5 A AC)
Range 2: 10 mV DC/AC per 1 A DC/AC (150 mV DC/AC for 150 A DC/AC)
- Standard accuracy from ≤2% (range 1); from ≤4% (range 2)
- DC zero adjustment with 20-turn potentiometer (± 1.5 A)
- IP20-rated housing
- LED indicator of correct battery voltage
- Electrical safety: 600 V CAT III, 300 V CAT IV
- Maximum diameter of the measured wire: 11.8 mm
- Output: two-core cable of about 1.5 m length terminated with two safe, male "banana" type terminals of 4 mm diameter
- Power supply: 9 V battery (operating time about 70 hours); Green LED for correct battery status (> 6.5 V)
- Dimensions: 231 mm x 36 mm x 67 mm
- Weight: about 330 g (with battery)