Product Overview
APPA A18+ is a multifunctional 4-digit clamp meter with a current range (AC and DC) up to 600A. The device at purchase comes with a carrying case, test leads, temperature probe adapter, temperature probe, battery and instruction manual.
Technical data
| - Direct current in the range up to 600A
- Alternating current in the range up to 600A
- DC voltage in the range up to 1000V
- Alternating voltage within the range up to 1000V
- Power in the range from 4kW to 600kW
- Power Factor measurement from -1.00 to 1.00
- THD harmonic content factor measurement from 0% to 100%
- Phase sequence test
- Inrush current measurement
- Frequency measurement up to 4kHz
- Temperature from -50°C to 1000°C
- Resistance in range up to 20kΩ
- Acoustic continuity test <30Ω
- Diode test
|
| |
| - LCD, 4-digit, 7-segment display
- Maximum display 6000
- Backlit display
|
| - Sampling rate of 3 times/s
- Maximum resolution 0.01V / 0.1A / 0.1Ω / 0.1Hz / 1W / 0.1°C
- Maximum diameter of the measured wire 35mm
- Reading memory (DATA HOLD function)
- Memory of peak values (PEAK HOLD function)
- Memory of minimum and maximum values (MIN./MAX. function)
- Measurement of the rms value of a signal of any shape (TrueRMS) in the range from 45 Hz to 500 Hz
- Battery discharge indicator
- Automatic power off after approx. 10 minutes
- Safe fully insulated test leads
- Safety (Cat. III 600V / Cat. II 1000V)
|
| - Test leads
- Temperature probe
- Temperature probe adapter
- Battery
- Case
- User manual
|
| |
Feature presentation
DAY & NIGHT
A10 series meters have a backlit screen,
activated and deactivated by a button.
After time, the backlight is also automatically turned off
backlighting to save battery life.
SLIM DESIGN
The slim design of the device makes it convenient to take
measurements using one hand. Thanks to the appropriate profiling,
device fits perfectly into the user's hand.
MEASUREMENT FUNCTIONALITY
The pliers allow to measure values on a cable with a diameter of up to 51 mm.
EASY BATTERY REPLACEMENT
When replacing batteries, simply unscrew one screw
and remove the cover cap.